Home ProductsType 2 Surge Protection Device

MAX 70kA Type 2 Surge Protection Device 4P Overvoltage Arrester 35mm Din Rail

MAX 70kA Type 2 Surge Protection Device 4P Overvoltage Arrester 35mm Din Rail

    • MAX 70kA Type 2 Surge Protection Device 4P Overvoltage Arrester 35mm Din Rail
    • MAX 70kA Type 2 Surge Protection Device 4P Overvoltage Arrester 35mm Din Rail
  • MAX 70kA Type 2 Surge Protection Device 4P Overvoltage Arrester 35mm Din Rail

    Product Details:

    Place of Origin: China
    Brand Name: BRITEC
    Certification: CE
    Model Number: BR-70 4P

    Payment & Shipping Terms:

    Minimum Order Quantity: 200 piece / pieces
    Packaging Details: EXPORT PACKING
    Delivery Time: 15-30 days after payment
    Payment Terms: T/T
    Supply Ability: 50000 pieces per month
    Contact Now
    Detailed Product Description
    Test Standards: IEC 61643-11 / EN61643-11 Uc: 150V / 275V / 320V / 385V
    In: 40kA Material: Thermal Plastic UL94-V0
    TA: ≤25ns Mounting On: 35mm Din Rail
    Imax: 70kA Tu: -40℃...+80℃

     

    Type 2 Surge Protection Device I MAX 70kA 4P Overvoltage Arrester 35mm Din Rail

     

    Feature:

     

    • • Class II, Type 2, 70kA
      • 70kA maximum surge current
      • Conforms to IEC 61643-11 and EN61643-11
      • Protection Against Indirect Lightning and Switching Surges
      • Simple DIN rail mounting IP20 Protection
      • Remote signaling selectable.

     

    Product Details:

     

      BR150 70 4P BR275 70 4P BR320 70 4P BR385 70 4P
    SPD classification according to EN61643-11 Type 2 Type 2 Type 2 Type 2
    SPD classification according to IEC61643-11 Class II Class II Class II Class II
    Max. continuous operating a.c. voltage     Uc 150V 275V 320V 385V
    Nominal discharge current (8/20us)           In 40kA 40kA 40kA 40kA
    Max. discharge current(8/20μs)             Imax 70kA 70kA 70kA 70kA
    Voltage protection level                                 Up ≤1.0kV ≤1.7kV ≤2.0kV ≤2.3kV
    Voltage protection level 5kA                         Up ≤0.5kV ≤0.9kV ≤1.1kV ≤1.3kV
    Max. backup fuse 200A gL 200A gL 200A gL 200A gL
    Response time                                           tA ≤25ns ≤25ns ≤25ns ≤25ns
    Operating temperature range                   Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
    Operating state / fault indication   green / red     green / red     green / red     green / red  
    Cross-section area (Min.) 4mm2 4mm2 4mm2 4mm2
    Cross-section area (Max.) 35mm2 35mm2 35mm2 35mm2
    For mounting on 35mm Din rail
    Enclosure material Thermal plastic UL94-V0
    Degree of protection IP20 IP20 IP20 IP20
    Order Code B8260 B8262 B8264 B8266
    Order Code (With remote signaling) B8261 B8263 B8265 B8267

     

    Technology characteristic:

     

    MAX 70kA Type 2 Surge Protection Device 4P Overvoltage Arrester 35mm Din Rail

     

    Application:

     

    • • In case of surge current or voltage caused by lightningstrike or similar, SPD functions quickly to
        conduct the surge voltage/current to earth and thus effectively prevent the downstream
        equipments of its protected line from destruction.
      • This SPD is particularly useful in a high lightning density area where the risk of heavy surge
        current or even direct strike is high (eg: buildings equipped with lightning rods).
      • This surge protection devices are recommended for locations having a high exposure to
        lightning, for example, light entrances to buildings protected by lightning rods or powered by
        aerial lines.
       

    Advantage:

     

    • • Pluggable cartridges on a fixed base plate, for easy installation and fast replacement.
      • Quick response less than 25ns
      • Mechanical status indicator

     

    Our Services:

     

    • • 10 years global leading profession manufacture of electrical products surge arrester
      • All products will be well packed before shipping
      • Standard packaging, and you can also tell us your own requirements on packaging
      • Faster delivery
      • Individually Tested Prior to Shipment

     

    Why do we need surge protection?

     

    • • There are not many areas of the world today that do not experience surge-related incidents.
        Lightning is only one of the many causes of transient surge related problems. Today's modern
        electronic equipment is much smaller, much faster, and much more susceptible to transient
        related problems than was the last generation of equipment. The sheer number of control and
        communication devices interlinked together in today's networks make their susceptibility many
        times greater. These are new problems that were not nearly as frequent with previous
        generations of control equipment.

     