Send Message
Home ProductsType 1 Surge Protection Device

BR-25GR 4P 50kA Class I Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester

BR-25GR 4P 50kA Class I Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester

  • BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester
  • BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester
  • BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester
  • BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester
  • BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester
Product Details:
Place of Origin: China
Brand Name: BRITEC
Certification: TUV/CB/ISO9001
Model Number: BR-25GR 4P
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece/Pieces
Packaging Details: EXPORT PACKING
Delivery Time: Shipped in 15 days after payment
Payment Terms: L/C, D/A, T/T, Western Union
Supply Ability: 50000 Piece/Pieces Month
Contact Now
Detailed Product Description
Item Name: Thunder Protector Type: Type1 Low Voltage Surge Arrestor
Pole: 4P In: 25kA
Backup Fuse: 315 Amps GL/Gg Imax: 100kA
Standard: CE MOQ: 1PCS
High Light:

4P low voltage surge arrester

,

class I low voltage surge arrestor

,

50kA low voltage spd

4P class I Surge Protection Device low voltage surge arrestor SPD
 

low voltage surge arrestor Product Description:

Type 1+2 surge protectors are heavy-duty devices, designed to be installed at the origin of the AC installations equipped with LPS (Lightning Protection System). They are necessary to protect sensitive equipment connected to AC network against direct and indirect effects of lightning. Following the different national electrical codes, these SPDs can be recommended or mandatory. These surge protectors are tested following Class I (T1, Class B) tests from IEC&EN 61643-11, characterized by 10/350 μs lightning current injections.

 
low voltage surge arrestor  Technology characteristic:
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 0

BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 1

 

Specification BR-25GR 4P
Item name Surge Arrester
SPD dassification according to EN61643-11 Type 1 + Type 2
SPD dassification according to EN61643-11 Class I + Class II

Max continuous 0perating a.c. voltage           Uc

275V
Lightning impulse current (10/350µs)           limp 25kA
Norminal discharge current (8/20µs)                In 25kA
Maximum discharge current (8/20µs)          Imax 100kA
Voltage protection level                                   Up ≤1.8kV
Follow current extinguishing capability a.c.      lifi 5kA rms
Max. backup fuse 315A gG
Response time                                                 tA ≤100ns
Operating temperature range                          Tu -40℃—80℃
Cross-section area (Min.) 4mm2
Cross-section area (Max.) 35mm2
For mounting on 35mm Din rail
Enclosure material Thermal plastic UL94-V0
Degree of protection IP20

 
 

thunder lightning arrester Feature:
 

· For electrical installations.

· Suitable for lightning protection of power supply system in areas with high risk of lightning strike (LPZ0B or interface between LPZ0B and LPZ1).

· Can handle lightning currents and protect sensitive electronic equipment.

· Application-optimized and prewired combined lightning current.

· Particularly useful in a high lightning density area where the risk of heavy surge current or even direct strike is high (e.g.: buildings equipped with lightning rods).

 
Type 1 SPD:
 
The Type 1 SPD is recommended in the specific case of service-sector and industrial buildings, protected by a lightning protection system or a meshed cage.
It protects electrical installations against direct lightning strokes.
It can discharge the back-current from lightning spreading from the earth conductor to the network conductors.
Type 1 SPD is characterized by a 10/350 µs current wave.
 
Our Services:
 
• 20 years global leading profession manufacture of electrical products surge arrester.
• All products will be well packed before shipping.
• Standard packaging, and you can also tell us your own requirements on packaging.
• Faster delivery.
• Individually Tested Prior to Shipment.
 
Installation:
 
• Used in the lightning protection zones concept at boundary LPZ0B-LPZ1.
• Suitable as the first step of protection in incoming power supply panels and areas with greater exposure to the atmosphere, where installations are usually provided with an external lightning protection system.
• Type 1 is placed at the entrance point of the installation, in the main distribution board for a global protection of this installation.
 
About us:
 
Wenzhou Britec Electric Co., Ltd. is a leading manufacturer and professional exporter, specialized in low voltage surge protection device products. Our products go well in Europe, South America, the Middle East, Southeast Asia and other countries and regions.
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 2
 
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 3
 
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 4
 
Certificatte:
Our products offer full range of SPD products which has CE, RoHS,TUV, SEMKO, CB certification.The company implements ISO9001 quality mangement system.
 
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 5
 
Shipping:
 
BR-25GR 4P 50kA Class I  Surge Arrestor SPD thunder protector lightning arrester 25ka power surge arrester 6
 
FAQ:
 

Q1: Selection of surge protector
Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of EN 61643-11 / IEC 61643-11 is 25 ka (10/350), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.
 
Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?
A2: We are a lightning surge protectors manufacturer.
 
Q3: Warranty and services:
A3:1. Warranty 5 years
2. lightning surge protectors products and accessories have been tested 3 times before ship out.
3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.
 
Q4: How can I get some lightning surge protectors samples?

A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.

 
Q5: Is the sample available and free?
AS: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.
 
Q6: Do you accept customized order?
A6: Yes, we do.
 
Q7: What’s the delivery time?
A7: It usually takes 7-15days after confirming payment, but a specific time should be based on the order quantity.

 
 

Contact Details
Britec Electric Co., Ltd.

Contact Person: Lucky Zhu

Tel: +8615888436909

Send your inquiry directly to us