Send Message
Home News

IEC 61643-21 Low voltage surge protective devices – Part 21: Surge protective devices connected to telecommunications and signalling networks – Performance requirements and testing methods

Company News
IEC 61643-21 Low voltage surge protective devices – Part 21: Surge protective devices connected to telecommunications and signalling networks – Performance requirements and testing methods
Latest company news about IEC 61643-21 Low voltage surge protective devices – Part 21: Surge protective devices connected to telecommunications and signalling networks – Performance requirements and testing methods

Description / Abstract:

 

This International Standard is applicable to devices for surge protection of telecommunications and signalling networks against indirect and direct effects of lightning or other transient overvoltages.

 

The specifications serve for compliance that the necessary requirements are met by low voltage surge protective devices used for protection in telecommunications and signalling networks. For this purpose, two basic types of circuits for low voltage surge protective devices are taken into consideration: those with exclusively voltage-limiting component and those with voltage- and current-limiting component in an enclosure.

 

The requirements stipulated for the low voltage surge protective devices concern general requirements for identification and product documentation, marking of low voltage surge protection devices and electrical, mechanical and environmental requirements.

 

The electrical requirements serve to ensure that the voltage and current-limiting functions as well as the signal transmission capabilities of the low voltage surge protective device fulfill their purpose.

 

Regarding voltage limitation, requirements for the maximum continuous operating voltage, insulation resistance, voltage limitation during impulse influence, the impulse re-set, AC durability, impulse durability for voltage limiting function, overstressed faults and the blind spot test multi stage SPD are provided.

 

Regarding current limitation, requirements for the nominal current, the series resistance, response time, current reset time, maximum disconnection voltage, the AC durability for current limiting function and the impulse durability for current limiting function are provided.

 

Moreover, an operating duty test is specified. Regarding the transmission capabilities, requirements for the capacitance, insertion and return loss, longitudinal balance, bit error ratio and near-end crosstalk loss are provided.

 

The mechanical requirements serve to ensure that the low voltage surge protective device demonstrates sufficient mechanical strength of the installation, is not damaged by ingress of solid objects, water or fire, and is sufficiently fire-resistant. Moreover, requirements regarding protection against direct contact are specified.

 

The environmental requirements serve to ensure that the low voltage surge protective device is not damaged by the environmental conditions (temperature, humidity). In order to test whether the low voltage surge protective device meets the requirements, corresponding test methods are specified in this standard.

 

With respect to the previous version of this standard, a series of individual specifications has been modified and supplemented, including the specified ranges of test temperature and ambient humidity.

 

Moreover, it has been included in corresponding sections of the standard text that AC low voltage surge protective devices running on alternating current, DC low voltage surge protective devices running on direct current and AC/DC low voltage surge protective devices running on direct current shall be tested.

 

In addition, two annexes with information regarding basic configurations for measuring the voltage protection level and regarding the subject of resistibility in telecommunication systems have been added.

 

 

Pub Time : 2023-12-28 15:10:13 >> News list
Contact Details
Britec Electric Co., Ltd.

Contact Person: Macy Jin

Tel: 0577-62605320

Fax: 86-577-61678078

Send your inquiry directly to us
Type 2 Surge Protection Device

BR-40 4P 40kA Surge Arrester Protection Device 3 Phase thunder protector spd tuv type 2 surge protection device

BR-40 2P Surge Protection Device Class II Spd 275v lightning surge protector varistor surge arrester

BR-40 4P 40kA 4 Pole 3 Phase tuv ac surge arrester surge Absorber Protection spd 275v lightning surge protector

BR-40 1+1 DIN Rail Type 2 Surge Protection Device Spd Lightning Protection

DC Surge Protection Device

BRPV3-1000 1000V 40kA 3P DC Solar PV Surge Protection device Surge Arrester Lightning Suppressor solar surge arrester

BRPV3-1000 40KA DC SPD Surge Protection Device Solar Photovoltaic Lightning Arrester surge protection t1 t2 dc

BR-40 48 DC SPD Surge Protection Device Dc Surge Suppressor 40kA 48v Pv Surge Arrester

BRPV2-600 600V DC Surge Protection Device Remote Signaling pv lightning arrester solar spd dc600v pv surge arrester

Type 1 Surge Protection Device

BR-25GR 4P 25kA 100kA britec surge protective device Type 1 3 Phase spd spark gap surge protection device

BR-50GR 4P Ac Lighting protection China type 1 surge protection device Spd Surge Filter spd t1 t2

BR-25GR 3P+1 Type 1 Surge Protection Device SPD Thunder Arrester spark gap spd Plug -in surge arrestor

BR-25M 4P Type 1 Surge Protection Device Lightning protection varistor SPD lightning protection

Request A Quote
Privacy Policy | China Good Quality Surge Protection Device Supplier. © 2018 - 2024 surge-protectiondevice.com. All Rights Reserved.