Home ProductsSurge Protective Device Type 3

Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester

Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester

  • Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester
  • Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester
Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester
Product Details:
Place of Origin: China
Brand Name: BRITEC
Certification: CE
Model Number: BR-10DP 1+NPE
Payment & Shipping Terms:
Minimum Order Quantity: 200 piece / pieces
Packaging Details: EXPORT PACKING
Delivery Time: 15-30 days after payment
Payment Terms: T/T
Supply Ability: 50000 pieces per month
Contact Now
Detailed Product Description
Test Standards: IEC 61643-11 / EN61643-11 Un: 24V / 60V / 120V / 230V
In: 5kA Material: Thermal Plastic UL94-V0
TA: ≤25ns Mounting On: 35mm Din Rail
Uoc: 10kV Tu: -40℃...+80℃
Item: Lightning Protection Device Type: Class III
High Light:

type 3 surge protector

,

ac surge protector

 
Power Line 10kV Lightning Protector Type 3 Class III 1+NPE 10kA Surge Arrester Device Din Rail
 
Feature:
 

  • • This product has a one-piece design.
    • Protection class: Type 3, Class III
    • Pole number: 1+NPE.
    • Optional remote status signaling.
    • The type 3 SPD has Uoc of 10kV.
    • Conforms to IEC61643-11 and EN61643-11.
    • Green-Red status indication.
    • Full range of Uc from 30V to 275V.

 
Product Details:
 

  BR30-10DP  1+NPEBR75-10DP 1+NPEBR150-10DP 1+NPEBR275-10DP 1+NPE
SPD classification according to EN61643-11Type 3Type 3Type 3Type 3
SPD classification according to IEC61643-11  Class IIIClass IIIClass IIIClass III
Nominal a.c. voltage                                    Un24V60V120V230V
Max. continuous operating a.c. voltage        Uc30V75V150V275V
Max. continuous operating d.c. voltage       Uc38V100V190V300V
Nominal discharge current (8/20us)              In5kA5kA5kA5kA
Combined impulse                                     Uoc10kV10kV10kV10kV
Voltage protection level                               Up≤200V≤500V≤700V≤1100V
Response time                                                   tA≤25ns≤25ns≤25ns≤25ns
Operating temperature range                       Tu-40℃-80℃-40℃-80℃-40℃-80℃-40℃-80℃
Operating state / fault indicationgreen / redgreen / redgreen / redgreen / red
Cross-section area (Min.)2.5mm22.5mm22.5mm22.5mm2
Cross-section area (Max.)16mm216mm216mm216mm2
For mounting on35mm Din rail
Enclosure materialThermal plastic UL94-V0
Degree of protectionIP20IP20IP20IP20
Order CodeB8337B8335B8333B8331
Order Code (With remote signaling)B8338B8336B8334B8332

 
Technology characteristic:
 
Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester 0
 
Application:
 

  • • To be installed in lowvoltage distributions at the boundary of LPZ 2 and LPZ 3 zones to protect
      distributions and equipment against overvoltage effects induced during a lightning strike and to
      prevent switching overvoltage.
    • To protect electric and electronic equipment connected to a low-voltage distribution against
      pulse overvoltage.
    • For protection of electric networks and equipment caused by atmospheric disturbances and
      from switching processes in networks.
    • For protection of common electric equipment in apartments, commercial buildings etc.
     

Advantage:
 

  • • Lower voltage protection level.
    • Visual fault signaling.
    • All-purpose surge arrester.
    • High discharge capacity
    • High reliability.
    • Slim design.


Our Services:
 

  • • 17 years global leading profession manufacture of electrical products surge arrester.
    • All products will be well packed before shipping.
    • Standard packaging, and you can also tell us your own requirements on packaging.
    • Faster delivery.
    • Individually Tested Prior to Shipment. 

 
Noted:
 

• Type 3 surge protective devices are generally installed right in front of the terminal device to be
  protected.
• Effective surge protection is not just simply installed. It has to be individually coordinated – to the
  system that is to be protected and the ambient conditions that are prevalent on site. For this reason,
  the design and concept must be consistent. This means many details must be taken into account,
  from considering the standards and stipulations right through to classification according to lightning
  protection zone.
• Surge protection should ensure that surge voltages cannot cause damage to installations, equipment
  or end devices.

 
Certification:
 
Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester 1
 
Our factory:
 
Britec Electric Wenzhou Co., Ltd. an export enterprise specialized in the manufacture of SPDs, our
factory was found in 2003. Which is located in Yueqing city, Zhejiang province, China.
 
Power Line 10kV Lightning Surge Protection Devices Class III 1+ NPE 10kA Surge Arrester 2
 
FAQ:
 
Q1. Payment:
  A: TT 30% deposit in advance and the balance before shipping.
 
Q2. Delivery time and methord:
  A: Usually within 15-30 days.
 
Q3. Port of loading:
  A: Shanghai or Ningbo port, China.
 
Q4. MOQ:
  A: 100PCS.
 
Q5. Package:
  A: Standard export packing--Carton.
 
 

Contact Details
Britec Electric Co., Ltd.

Contact Person: Xu

Tel: +8615657751280

Send your inquiry directly to us
Other Products