Product Details:
|
| Item Name: | Surge Protector | Material: | Thermoplastic |
|---|---|---|---|
| Pole Number: | 3P | Protection: | IP20 |
| Tu: | -40℃-80℃ | Uc: | 275V |
| In: | 30kA | Imax: | 60kA |
| Up: | ≤1.5kV | Usage: | Low Voltage |
| Keyword: | Lightning Protection | Standard: | IEC/EN 61643-11 |
| Highlight: | lightning protection device,lightning surge protector |
||
The 3 Pole SPD 275V Power Surge Protector (60kA T2 MOV Surge Protective Device) is a Type 2 / Class II device engineered to safeguard three-phase TN-C systems against indirect lightning discharges and voltage spikes. It combines a high-performance varistor with a thermal disconnection tripping device and a plug-in module/base design that allows failed modules to be replaced without disturbing system wiring.
| BR-60 275 3P | |
|---|---|
| Max. continuous operating a.c. voltage (Uc) | 275V |
| Nominal discharge current (8/20µs) (In) | 30kA |
| Max. discharge current (8/20µs) (Imax) | 60kA |
| Voltage protection level (Up) | ≤1.5kV |
| Response time (tA) | ≤25ns |
| Max. backup fuse | 200A gG |
| Operating temperature range (Tu) | -40℃ to 80℃ |
| Cross-section area (Min.) | 4mm² |
| Cross-section area (Max.) | 35mm² |
| For mounting on | 35mm DIN rail |
| Enclosure material | Thermoplastic UL94-V0 |
| Dimension | 3 mods |
| Test standards | IEC 61643-1 |
Quality is our foremost consideration. We offer a wide range of surge protection devices, and our workers have over 23 years of experience in our factory. We are professional manufacturers of various surge protection devices, including both power and signal types.
Q1: Are you a trading company or a manufacturer?
A: We are a factory.
Q2: How long is your delivery time?
A: Generally within 7 days if the goods are in stock; otherwise less than 30 days, depending on quantity.
Q3: Do you provide samples?
A: Yes, we can offer samples.
Q4: What are your terms of payment?
A: 30% T/T in advance, balance before shipment.
Q5: How do I select a 3 pole SPD for a 230/400V TN-C low voltage system?
A: Choose a Type 2 (Class II) device with a maximum continuous operating voltage Uc of 275V AC in a 3 pole configuration for three-phase TN-C distribution, then verify that the nominal discharge current In and the voltage protection level Up match your installation.
Q6: What is the difference between In 30kA and Imax 60kA on this surge protector?
A: In 30kA is the nominal discharge current tested with the 8/20 microsecond waveform that the SPD handles repeatedly without degradation, while Imax 60kA is the maximum single discharge current it withstands without damage.
Q7: What backup fuse is required for the BR-60 275 3P SPD?
A: IEC/EN 61643-11 recommends a maximum 200A gG backup fuse, and the terminals accept conductors from 4 square millimeters to 35 square millimeters.
Q8: How can I tell when the surge protection module needs replacing?
A: The green status window changes state once the varistor reaches end of life, and the plug-in module can then be replaced on its base without removing the existing system wiring.
Q9: What does the 1.5kV voltage protection level mean for downstream equipment?
A: A voltage protection level Up of 1.5kV or lower means the residual voltage at the SPD terminals is limited to 1.5kV during a surge, with a response time of 25 nanoseconds or less, protecting equipment rated above that level.
Q10: Can this type 2 surge protector be installed outdoors or in hot locations?
A: It is rated IP20 for indoor mounting inside distribution enclosures, operates from minus 40 degrees Celsius to 80 degrees Celsius, and is CE certified to IEC/EN 61643-11.