Type 1
Type 1 Surge Protective Device (SPD)s are intended for installation between the secondary of the service transformer and the line side of the service equipment overcurrent device, as well as the load side, including watt-hour meter socket enclosures, and are intended to be installed without an external overcurrent protective device. Type 1 devices are dual-rated for Type 2 applications as well, providing the highest ratings available for installation at the service entrance.
Type 1 SPD can discharge lightning current with waveform 10/350μs. This, if required, will be in-stalled in the primary distribution board at the origin of the electrical installation. A Type 1 SPD does not in itself offer the required protection level and must be used in conjunction with coordinated type 2 devices. An installation with a lightning protection system will require a Type 1 SPD.
Type 2
Type 2 Surge Protective Device—Type 2 SPDs are intended for installation on the load side of the service equipment overcurrent device, including SPDs located at the branch panel.
Type 2 SPD can discharge 8/20μs current wave , they can prevent the damage of transient overvoltage in the electrical installations and protects equipment connected to it. It usually employs metal oxide varistor (MOV) technology. The device would normally be installed in sub-distribution boards and in the primary distribution board if there was no requirement for a type 1 device
Type 3
These SPDs have a low discharge capacity. They must therefore only be installed as a supple-ment to Type 2 SPD and in the vicinity of sensitive loads. Type 3 SPD’s are characterized by a combination of voltage waves (1.2/50 μs) and current waves (8/20 μs).
Type 3 SPDs are normally installed right before the protected equipment.
Terminology
Iimp – Impulse current of Type 1 SPDs with 10/350 μs waveform
In – Norminal discharge current of Type 2 SPDs with 8/20 μs waveform
Imax- Maximum discharge current of Type 2 SPDs with 8/20 μs waveform
Up - The residual voltage that is measured across the terminal of the SPD when In is applied
Uc - The maximum voltage which may be continuously applied to the SPD without damage the SPD
Britec Electric offers full range of surge protective devices including Type 1, Type 1+2, Type 2 and Type 3 SPDs.
Contact Person: Macy Jin
Tel: 0577-62605320
Fax: 86-577-61678078
BR-40 2P Surge Protection Device Class II Spd 275v lightning surge protector varistor surge arrester
BR-40 1+1 DIN Rail Type 2 Surge Protection Device Spd Lightning Protection
BR-40 48 DC SPD Surge Protection Device Dc Surge Suppressor 40kA 48v Pv Surge Arrester
BRPV2-600 600V DC Surge Protection Device Remote Signaling 600v pv lightning arrester solar spd
BR-50GR 4P Ac Lighting protection China type 1 surge protection device Spd Surge Filter spd t1 t2
BR-25M 4P Type 1 Surge Protection Device Lightning protection varistor SPD lightning protection