Home ProductsType 1 Surge Protection Device

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices

  • Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices
  • Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices
  • Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices
  • Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices
Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices
Product Details:
Place of Origin: China
Brand Name: BRITEC
Certification: TUV
Model Number: BR-50GR 385 4P
Payment & Shipping Terms:
Minimum Order Quantity: 100 Piece/Pieces
Packaging Details: EXPORT PACKING
Delivery Time: Shipped in 15 days after payment
Payment Terms: L/C, D/A, T/T, Western Union
Supply Ability: 50000 Piece/Pieces Month
Contact Now
Detailed Product Description
Item Name: Lightning Surge Arrester Type: Ac Surge Protector
Material: Plastic Pole Number: 4P
Enclosure: Thermalplastic UL94-VO Certificate: TUV/CE/ROHS/ISO9001
Tu: -40℃-80℃ Application: Surge Protective Device Is Suitable For Single-phaseTN System
High Light:

industrial surge protection devices

,

type 1 surge protector

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices

 

Features:
 
  • • Impact discharge current of per pole reaches 50kA(10/350).
    • Fast response time less than <100ns.
    • Max. backup Fuse: 500A.
    • Status indicator.
    • Fault signal contact.
    • 35mm Din rail mountable.
    • BR-50GR 4P is suitable for TN-S system.
    • It has passed the class I lightning protection test conducted by national professional
  •   testing institutions.
    • It is the first-level lightning protection product of ac power equipment.
 

Technology characteristic:

 

Specification BR-50GR 385 4P
Item name Surge Arrester
SPD dassification according to EN61643-11 Type 1
SPD dassification according to EN61643-11 Class I
Max continuous 0perating a.c. voltage           Uc 385V
Lightning impulse current (10/350µs)           limp 50kA
Norminal discharge current (8/20µs)                In 50kA
Voltage protection level                                   Up ≤2.5kV
Follow current extinguishing capability a.c.      lfi 3kA rms
Max. backup fuse 500A gG
Response time                                                 tA ≤100ns
For mounting on 35mm Din rail
Degree of protection IP20
Payment term 30% deposit in advance,70% before shipment,100% T/T in advance
Certificate CB/CE/ROHS/ISO9001
Logo Customized logo available

 

Dimension:

 

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices 0

 

Application:

 

• For electrical installations.
• Suitable for lightning protection of power supply system in areas with high risk of lightning strike
  (LPZ0B or interface between LPZ0B and LPZ1).
• Can handle lightning currents and protect sensitive electronic equipment.
• Application-optimised and prewired combined lightning current.
• Particularly useful in a high lightning density area where the risk of heavy surge current or even direct
  strike is high (eg: buildings equipped with lightning rods).
 
Advantage:
 
• High lightning current discharge capacity.
• High quality lightning protection components.
• High reliable quality assurance.
• Temperature control trip device.
• Long service life.
• Failure indication.
• Fast response time.
• Competitively priced against other brands.
 
Our Services:
 
• 17 years global leading profession manufacture of electrical products surge arrester.
• All products will be well packed before shipping.
• Standard packaging, and you can also tell us your own requirements on packaging.
• Faster delivery.
• Individually Tested Prior to Shipment.
 
Installation:
 
• During installation, please connect according to the installation schematic diagram.
• Power must be cut off during installation, live operation is strictly prohibited, connecting wires must
  meet the requirements.
• Lightning protection grounding should meet the lightning protection specifications, the grounding wire
  should be as short as possible.

 

Company information:

 

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices 1

 

Certification:

 

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices 2

 

Test:

 

Thermalplastic Spd Surge Protector IP20 , 4 Pole Lightning Surge Protection Devices 3

 

FAQ:

 

Q1: Do you sell SPDs?
  A: Yes, all kinds of surge protection (SPDs) can be sold, please contract us for further details.

 

Q2: Are you a factory or trading company?
  A: We are a factory, we provide ODM& OEM services.

 

Q3: How do you ship the goods and how long does it take to arrive?
  A: We usually ship by TNT, DHL, UPS, FedEx or EMS. It usually takes 5-7 days to arrive. Airline and

      sea shipping also optional.

 

Q4: How about your quality control system?
  A: It’ll be 100% tested before packing, all of our products will pass strictly QC procedure before shipping.

 

Q5: Is it OK for us to visit your factory for lightning arrester?
  A: You are always warm welcome to visit our factories. We are located in Yueqing city, Zhejiang province.

 

 

Contact Details
Britec Electric Co., Ltd.

Contact Person: Xu

Tel: +8615657751280

Send your inquiry directly to us
Other Products